LyoTwist – the intuitive dual-chamber monodose device

Twisting to reconstitute is obvious

The LyoTwist monodose device family for dual-chamber cartridges is based on Ypsomed’s proven twisting method for reconstitution and priming. The devices provide excellent visualisation of the reconstitution, priming and injection steps. A complete range of device versions ensure that various drug, therapy and patient needs are met.

  • Intuitive and proven twisting method for reconstitution and priming for maximum patient acceptance
  • Excellent cartridge visualisation provides direct feedback to the patient
  • The correct handling sequence is ensured by design minimizing the risk of handling errors
  • Reconstitution and priming positions clearly indicated with visual markings and audible “click” signals for increased patient confidence
  • Different device options available to fulfil a broad spectrum of therapeutic needs
  • Built-in needle safety in combination with Clickfine AutoProtect safety pen needles

Discover the most advanced automatic reusable pen

LyoTwist

Handling steps For fixed dose versions

Mix and Prime
Inject

Handling steps For variable dose versions

Mix and Prime
Select dose
Inject

Device versions From manual to automatic and fixed to variable dosing

The LyoTwist device family covers a wide range of single-dose delivery needs based on a dual-chamber cartridge. In addition to selecting the appropriate technical solution we are able to customize the LyoTwist according to your individual drug and therapy needs.

LyoTwist Trio

  • Manual injection
  • Single fixed dose

LyoTwist Vario

  • Manual injection
  • Single variable dose
  • Up to 6 dose settings

LyoTwist Trio S

  • Automatic injection
  • Single fixed dose

LyoTwist Vario S

  • Automatic injection
  • Single variable dose
  • Up to 8 dose settings

Customisation and manufacturing

  • Simple mechanical design optimised for high volume manufacturing at minimal cost
  • Dose volume easy to customise

Benefits

The intuitive solution Simple and safe reconstitution and injection

Handling

  • Intuitive and proven twisting method for reconstitution and priming for maximum patient acceptance
  • Transparent cartridge holder provides full visualisation of the cartridge for maximum patient confidence
  • Dose button locked until reconstition and priming are completed ensuring intuitive handling
  • Audible and tactile end-of-injection “click” increases confidence and compliance
  • Different device options available to fulfil a broad spectrum of therapeutic needs

All LyoTwist injection devices have obvious markings showing reconstitution and priming positions and a fully transparent cartridge holder ensuring maximum visual control over the reconstitution process.

Dimensions Facts and figures

Device specifications
  • Min. dose0.1 mL
  • Max. dose1.0 mL
  • Compatible needle typeCompatible with standard and safety pen needles* – mylife Clickfine and mylife Clickfine AutoProtect pen needles recommended

* Pen needles according to ISO 11608-2

Cartridge dimensions (mm)

The LyoTwist can accommodate a range of dual-chamber cartridge formats.
The LyoTwist can accommodate a range of dual-chamber cartridge formats.